Beard Marine Home


Aquamini

170 & 350 U.S. gal. (644 & 1,325 litres) per day
7 & 15 U.S. gal. (27 & 55 litres) per hour



To see the various accessories available for the Aquamini, click on Accessories.


Specifications

PERFORMANCE:
RATED PERFORMANCE / PRODUCT WATER PRODUCED:
+-15% at 850 PSI / 59 BAR, 77oF / 25oC & 35,000 PPM TDS typical sea water

Model #
Per Hour
Per Day
Weight of System
Aquamini
7 & 15 gal/27 & 55 lit

170 & 350 gal /644 & 1,325 lit

105 lbs/48 Kg

AW 170 reverse osmosis desalinator diagram

SALT REJECTION (CHLORIDE ION): Minimum 99.2%, Average 99.4%

PRODUCT WATER TEMPERATURE: Ambient to feed water temperature

SALINITY MONITORING: Automatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design.

SALINITY RANGE: Designed for Seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

TEMPERATURE RANGE: Max. 122oF / 33oC, Min. 33oF / .5oC

SYSTEM FEED WATER: FLOW: 50 Hz, 4.2 gpm / 1.59 lpm; 60 Hz, .5 gpm/1.89 lpm

REVERSE OSMOSIS MEMBRANE: Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

CHLORINE TOLERANCE: 0.1 PPM

pH RANGE: 3-11 (typical seawater pH is 8)

SYSTEM PRESSURE: FEED WATER: Maximum 30 psi / 2.07 bar / 2.11 Kg/cm2

SYSTEM OPERATION: Seawater nominal 850 psi / 59 bar / 59.7 Kg/cm2 Brackish Varies w/PPM

EXTERNAL INSTALLATION WATER CONNECTIONS: Pipe sizes to be supplied by the installer for connection of the Sea Recovery supplied components.

Feed Inlet: 3/8" Tube (Parker Fast & Tite Fittings)
Brine Discharge: 3/8" Tube (Parker Fast & Tite Fittings)
Product: 1/4" Tube (Parker Fast & Tite Fittings)

ELECTRICAL POWER REQUIREMENTS: (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)

Alternating Current Systems:

Hz VAC HP FLA LRA
50     110         .333 6 26
50 220 .333 3 13
60 115 .333 6 26
60 230 .333 3 13

Booster Pump Motors:

Hz VAC HP FLA LRA
50/60 115 .125 4 20
50/60 220/230 .125 2 10

Direct Current Systems:

High Pressure Motor             Booster Pump Motor

VDC HP FLA VDC HP FLA
12 .33 29   12 .125 3
24 .33 14 24 .125 2

RECOMMENDED CIRCUIT BREAKER: The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.

Operating Voltage Hz & Phase

Recommended Circuit Breaker Size

12 VDC
24 VDC
115 VAC
230 VAC

40 Amperes
20 Amperes
10 Amperes
5-7.5 Amperes


Contact us for more information.